The HVAC control module monitors the evaporator temperature via the evaporator temperature sensor. When the air is cold, the sensor resistance and signal voltage are high. When the air is warm, the sensor resistance and signal voltage are low.
This diagnostic procedure supports the following DTC:
DTC B3933 Evaporator Temperature Sensor Circuit
The ignition is turned ON.
The HVAC control module detects the evaporator temperature sensor signal circuit is less than 0.09 volt (5 counts) or greater than 4.90 volts (250 counts).
• | The A/C OFF segment will illuminate on the HVAC control module. |
• | The A/C compressor will be disabled. |
• | The DTC will become history if the HVAC control module no longer detects a failure. |
• | The history DTC will clear after 50 fault-free ignition cycles. |
• | The DTC can be cleared with a scan tool. |
The numbers below refer to the step numbers on the diagnostic table.
This step tests for the proper operation of the circuit in the high voltage range.
This step tests for the proper operation of the circuit in the low voltage range. If the fuse in the jumper opens upon performing this test, the signal circuit has a short to voltage.
Step | Action | Values | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: Component Connector End Views | ||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||||||
2 |
Does the scan tool indicate that the Evaporator temp parameter is within the specified range? | 0.09-4.90 V | Go to Step 3 | Go to Step 4 | ||||||||||
3 | Check the connections at the Climate Control Panel and replace the terminals if necessary. Is the repair complete? | Go to Step 4 | ||||||||||||
Is the Evaporator Temp parameter greater than the specified value? | 4.90 V | Go to Step 5 | Go to Step 6 | |||||||||||
Is the Evaporator Temp parameter less than the specified value? | 0.09 V | Go to Step 10 | Go to Step 7 | |||||||||||
6 | Test the signal circuit of the evaporator temperature sensor for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 11 | ||||||||||
7 | Test the signal circuit of the evaporator temperature sensor for one of the following conditions:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 8 | ||||||||||
8 | Test the low reference circuit of the evaporator temperature sensor for one of the following conditions:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 9 | ||||||||||
9 | Test the following signal circuits for a short to voltage:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 11 | ||||||||||
10 | Inspect for poor connections at the harness connector of the evaporator temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 12 | ||||||||||
11 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 13 | ||||||||||
12 | Replace the evaporator temperature sensor. Refer to Air Conditioning Evaporator Core Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- | ||||||||||
13 | Replace the HVAC control module. Refer to HVAC Module Assembly Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- | ||||||||||
14 |
Does the DTC reset? | -- | Go to Step 2 | System OK |