Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics . Connector End View Reference: Component Connector End Views . DEFINITION: The blower motor operates in at least one, but not all, speed positions. | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 |
Are any blower speeds available? | Go to Step 4 | Go to Step 3 |
3 | Check for blown blower motor fuse 9 Was the fuse blown? | Replace the fuse with the correct amperage fuse. | Go to Step 4 |
4 | Check for power at the blower motor. Circuit Testing and Wiring Repairs . Is voltage available, but the blower motor will not operate? | Replace the blower motor. Refer to Blower Motor Replacement . | Go to Step 5 |
5 |
Are all blower speeds available? | Go to Step 9 | Go to Step 6 |
6 |
Were the voltages approximate to the graph? | Go to Step 9 | Go to Step 7 |
7 | Connect scan tool. Go to miscellaneous test, switch data. Select all 20 blower fan speeds using the scan tool increase / decrease soft keys Were all speeds available? | Carry out IRC test for blower switch function. | Go to Step 8 |
8 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you find and correct the condition? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |