1-2 Shift Error: This parameter displays the difference between
the desired 1-2 shift time and the actual 1-2 shift time. A positive number indicates
a firm or fast shift, the actual shift time was shorter than the desired shift time.
A negative number indicates a soft or slow shift, the actual shift time was longer
than the desired shift time. This value is only accurate if the shift was adaptable.
1-2 Shift Time: This parameter displays the actual time of the
last 1-2 shift. The shift time is based on the engine RPM drop after the commanded
1-2 shift. This value is only accurate if the shift was adaptable.
1-2 Sol.: This parameter displays the commanded state of the
1-2 shift solenoid valve. When the transmission is in FIRST and FOURTH gear, the display
should indicate ON, current is flowing through the solenoid. When the transmission
is in SECOND and THIRD gear, the display should indicate OFF, current is not flowing
through the solenoid.
1-2 Sol. Open/Short to GND: This parameter displays whether
an open or a short to ground exists in the 1-2 shift solenoid valve feedback
signal and displays Yes or No. The 1-2 shift solenoid valve must be commanded
OFF for this parameter to be valid.
1-2 Sol. Short to Volts: This parameter displays if a short
to voltage exists in the 1-2 shift solenoid valve feedback signal. This parameter
is valid only when the 1-2 shift solenoid valve is commanded ON. The scan tool will
display YES or NO.
1-2 Tap Cell (4-16): This parameter displays the amount
of transmission adaptive pressure (TAP), based on 17 N·m (12.5 lb ft)
of engine torque increment per cell, added to or subtracted from shift pressure during
a 1-2 up shift. A positive number indicates that long shifts have been detected and
PC solenoid pressure has been added in order to decrease shift time. A negative number
indicates that short shifts have been detected and PC solenoid pressure has been subtracted
in order to increase shift time.
2-3 Shift Error: This parameter displays the difference between
the desired 2-3 shift time and the actual 2-3 shift time. A positive number indicates
a firm or fast shift, the actual shift time was shorter than the desired shift time.
A negative number indicates a soft or slow shift, the actual shift time was longer
than the desired shift time. This value is only accurate if the shift was adaptable.
2-3 Shift Time: This parameter displays the actual time of the
last 2-3 shift. The shift time is based on the engine RPM drop after the commanded
2-3 shift. This value is only accurate if the shift was adaptable.
2-3 Sol.: This parameter displays the commanded state of the
2-3 shift solenoid valve. When the transmission is in FIRST and SECOND gear the display
should indicate ON, current is not flowing through the solenoid. When the transmission
is in THIRD and FOURTH gear, the display should indicate OFF, current is flowing through
the solenoid.
2-3 Sol. Open/Short to GND: This parameter displays whether
an open or a short to ground exists in the 2-3 shift solenoid valve feedback signal
and displays Yes or No. The 2-3 shift solenoid valve must be commanded OFF for this
parameter to be valid.
2-3 Sol. Short to Volts: This parameter displays if a short
to voltage exists in the 2-3 shift solenoid valve feedback signal. This parameter
is valid only when the 2-3 shift solenoid valve is commanded ON. The scan tool will
display YES or NO.
2-3 Tap Cell (4-16): This parameter displays the amount
of transmission adaptive pressure (TAP), based on 17 N·m (12.5 lb ft)
of engine torque increment per cell, added to or subtracted from shift pressure during
a 2-3 up shift. A positive number indicates that long shifts have been detected and
PC solenoid pressure has been added in order to decrease shift time. A negative number
indicates that short shifts have been detected and PC solenoid pressure has been subtracted
in order to increase shift time.
3-2 Downshift Sol.: This parameter displays if the 3-2 shift
solenoid valve assembly is currently commanded ON or OFF. The solenoid commanded state
is based on the transmission temperature. The solenoid will change states during a
3-2 downshift to regulate the appropriate pressure. The commanded state of the solenoid
occurs at approximately 30 mph with a throttle increase. The scan tool displays
ON or OFF.
3-2 Sol. Open/Short to GND: This parameter displays whether
an open or a short to ground exists in the 3-2 shift solenoid valve feedback signal
and displays Yes or No. The 3-2 shift solenoid valve must be commanded OFF for this
parameter to be valid.
3-2 Sol. Short to Volts: This parameter displays if a short
to voltage exists in the 3-2 shift solenoid valve feedback signal. This parameter
is valid only when the 3-2 shift solenoid valve is commanded ON. The scan tool will
display YES or NO.
3-4 Shift Error: This parameter displays the difference between
the desired 3-4 shift time and the actual 3-4 shift time. A positive number indicates
a firm or fast shift, the actual shift time was shorter than the desired shift time.
A negative number indicates a soft or slow shift, the actual shift time was longer
than the desired shift time. This value is only accurate if the shift was adaptable.
3-4 Shift Time: This parameter displays the actual time of the
last 3-4 shift. The shift time is based on the engine RPM drop after the commanded
3-4 shift. This value is only accurate if the shift was adaptable.
Calc. Throttle Position: This parameter displays a calculated
value, which is determined by the accelerator pedal position and the actual throttle
position, used to optimize transmission controls. It represents the driver's intended
request for torque or acceleration. The range is 0-100 percent, where 0 percent
represents an idle or coast request and 100 percent represents a request for wide
open throttle (WOT).
Commanded Gear: This parameter displays the current commanded
state of the shift solenoid valves. The scan tool displays 1, 2, 3, 4 or 5.
Current TAP Cell: This parameter displays the current transmission
adaptive pressure (TAP) cell in use for transmission line pressure adaptation. The
cells are based on 17 N·m (12.5 lb ft) of engine torque.
The higher the engine torque, the higher the current TAP cell. The last cell used
will remain displayed until the next adaptable up shift occurs.
ECT: This parameter displays the input signal from the ECT sensor.
Engine coolant temperature is high at 151°C (304°F) when the signal voltage
is low (0 volts). Engine coolant temperature is low at -40°C (-40°F)
when the signal voltage is high (5 volts).
Engine Speed: This parameter displays the rotational speed of
the engine expressed as revolutions per minute.
Engine Torque: This parameter displays a calculated value based
on engine load, throttle position, mass air flow, and other engine inputs. This parameter
is accurate to within 15 ft/lb of actual measured engine torque.
Estimated Gear Ratio: This parameter displays the estimated
turbine speed divided by the transmission output speed. Estimated turbine speed is
calculated from engine speed and engine torque.
Ignition Voltage: This parameter displays the system voltage
measured at the ignition feed.
Last Shift Time: This parameter displays the actual time of
the last up shift. This value is only accurate if the shift was adaptable.
PC Sol. Actual Current: This parameter displays the actual current
flow through the pressure control solenoid circuit which is measured by the control
module. High current flow results in low line pressure. Low current flow results in
high line pressure.
PC Solenoid Duty Cycle: This parameter displays the commanded
state of the pressure control solenoid expressed as a percentage of energised ON time.
A reading of low percent indicates zero ON time, non energised, or no current flow.
A high percent at idle indicates maximum ON time, energised, or high current flow.
PC Sol. Ref. Current: This parameter displays the commanded
current of the pressure control solenoid circuit. High current results in low line
pressure. Low current results in high line pressure.
Speed Ratio: This parameter displays the calculated speed ratio
of the transmission. The ratio is calculated by dividing the output speed sensor signal
by the input speed sensor signal. Gear ratio in a step-gear transmission is calculated
in the opposite manner.
TCC Brake Switch: This parameter displays the status of the
TCC brake switch circuit input. OPEN indicates a zero voltage input, brake pedal applied.
CLOSED indicates a voltage input, brake pedal released. The scan tool display OPEN
or CLOSED.
TCC Duty Cycle: This parameter displays the commanded percentage
of ON time of the TCC PWM solenoid. A high percentage represents an ON, energised,
commanded state. Zero percent represents an OFF, non-energised, commanded state.
TCC Duty Cycle Open/Short to GND: This parameter displays whether
an open or a short to ground exists in the torque converter clutch (TCC) pulse
width modulation (PWM) solenoid valve feedback signal and displays Yes or No. The
TCC PWM solenoid valve must be commanded OFF for this parameter to be valid.
The scan tool will display Yes only while the TCC PWM solenoid valve is OFF.
The display will pulsate.
TCC Duty Cycle Short to Volts: This parameter displays whether
a short to voltage, exists in the TCC PWM solenoid valve feedback signal and
displays Yes or No. The TCC PWM solenoid valve must be commanded ON for this
parameter to be valid. The scan tool will display Yes only while the TCC PWM
solenoid valve is ON. The display will pulsate.
TCC Enable Sol.: This parameter displays the commanded state
of the TCC solenoid. Yes indicates a commanded energised state, current is flowing
through the solenoid. No indicates a commanded non-energised state, current is not
flowing through the solenoid. This commanded state occurs at various vehicle speeds
between applications. The scan tool displays Yes or No.
TCC Enable Open/Short to GND: This parameter displays whether
an open or a short to ground exists in the TCC solenoid valve feedback signal. This
parameter is valid only when the TCC solenoid is commanded OFF. The scan tool displays
Yes or No.
TCC Enable Short to Volts: This parameter displays whether a
short to voltage exists in the TCC solenoid valve feedback signal. This parameter
is valid only when the TCC solenoid is commanded ON. The scan tool displays Yes or
No.
TCC Slip Speed: This parameter displays the difference between
transmission output speed and engine speed. A negative value indicates that the engine
speed is less than the output speed, deceleration. A positive value indicates that
the engine speed is greater than the output speed, acceleration. A value of zero indicates
that the engine speed is equal to the output speed, TCC applied.
TFP Sw.: This parameter displays Park/Neutral, Reverse, Drive4,
Drive3, Drive2, Drive1 or Invalid. This parameter is the decoded status of the three
A/B/C inputs from the automatic transmission fluid pressure manual valve position
switch. If a valid combination of inputs is not detected, invalid will be displayed.
TFP Sw. A/B/C: This parameter displays HI/LOW, HI/LOW, HI/LOW.
This parameter indicates the status of the three inputs from the Automatic Transmission
Fluid Pressure Manual Valve Position Switch Assembly. LOW represents a zero voltage
signal. HI represents an ignition voltage signal.
Torque Converter Efficiency: This parameter displays a ratio
of 0.00:1 to 2:1. The ratio is calculated by multiplying the speed ratio by a value
related to the "K factor" of the torque converter. The "K factor" is the looseness
or tightness of the torque converter for a given torque. The nearer the torque converter
is to full coupling, i.e. 1:1, the closer the torque converter efficiency number will
be to 1.
TP Indicated Angle: This parameter displays the desired throttle
angle for operating conditions present at the time.
TR Sw.: This parameter displays the decoded status of the four
A/B/C/P inputs from the transmission range switch. The scan tool displays Park, Reverse,
Neutral Drive, Intermediate, Low, and Invalid. If a valid combination of inputs is
not detected, invalid will be displayed.
TR Sw. A/B/C/P: This parameter displays the status of the four
inputs from the transmission range switch. The scan tool displays HI/LOW. HI indicates
an ignition voltage input to the control module. LOW indicates a zero voltage input
to the control module.
Trans. Fluid Temp.: This parameter displays the input signal
of the transmission fluid temperature sensor. Transmission fluid temperature is high
151°C (304°F) when signal voltage is low, 0 volts, and transmission
fluid temperature is low -40°C (-40°F) when signal voltage is
high, 5 volts.
Trans. Slip Counter: This parameter displays the number of times
the P0894 Diagnostic test has identified a slipping condition. This diagnostic test
is required to identify a slipping condition three times in a row in order to set
the DTC P0894 Transmission Component Slipping Diagnostic code. The scan tool
displays 0, 1 or 2.
Transmission Hot Mode: This parameter displays the automatic
transmission fluid temperature (TFT) and displays ON or OFF. OFF indicates that the
TFT has not exceeded 130°C (266°F). ON indicates that the TFT has exceeded
130°C (266°F) and has not cooled to 120°C (248°F) for more that 5 seconds.
Note: these numbers are approximate. They differ with transmissions.
Transmission OSS: This parameter displays the rotational speed
of the transmission output shaft expressed as revolutions per minute.
Vehicle Speed: This parameter displays the speed at which the
vehicle is traveling. The scan tool displays vehicle speed as kilometers per hour
(km/h), (miles per hour (MPH)). The vehicle speed is calculated based on the input
signal from the vehicle speed sensor.