The numbers below refer to the step numbers on the diagnostic table.
This step checks for proper cooling system operation.
The voltage will vary between 0-12 volts during normal operation. The HVAC control module connector must be connected during this step.
Step | Action | Values | Yes | No | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Temperature cannot be adjusted or heating insufficient. | ||||||||||||||||||
1 | Did you review the HVAC operation and perform the necessary inspections? | -- | Go to Step 2 | |||||||||||||||
2 |
Does the blower motor operate in any of the speed positions? | -- | Go to Step 3 | Go to Blower Motor Inoperative | ||||||||||||||
3 | Does the blower motor operate in each speed position? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||||||||
4 | Turn the blower motor fan ON and select an air outlet mode. Does air flow out of the selected HVAC outlet ducts? | -- | Go to Step 5 | Go to Air Delivery Improper | ||||||||||||||
Inspect the cooling system for the following conditions:
Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 6 | |||||||||||||||
6 |
Does the A/C compressor operate? | -- | Go to Step 7 | |||||||||||||||
7 |
Does the voltage measure within the specified values with a smooth transition between COLD to HOT? | 0.5-4.5 V | Go to Step 10 | Go to Step 8 | ||||||||||||||
8 |
Does voltage measure near the specified value? | 5 V | Go to Step 9 | Go to Step 13 | ||||||||||||||
9 | Inspect the air temperature door and the air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 10 | ||||||||||||||
Does the voltage measure near specified value? | 1-12 V | Go to Step 16 | Go to Step 11 | |||||||||||||||
11 | Test the door control A circuit of the air temperature actuator for an open, a high resistance, a short to ground, or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 12 | ||||||||||||||
12 | Test the door control B circuit of the air temperature actuator for an open, a high resistance, a short to ground, or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 13 | ||||||||||||||
13 | Test the 5-volt reference circuit of the air temperature actuator for an open, high resistance, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 14 | ||||||||||||||
14 | Test the signal circuit of the air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 15 | ||||||||||||||
15 | Test the low reference circuit of the air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 17 | ||||||||||||||
16 | Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 18 | ||||||||||||||
17 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 19 | ||||||||||||||
18 | Replace the air temperature actuator. Refer to Temperature Valve Actuator Replacement . Did you complete the replacement? | -- | Go to Step 20 | -- | ||||||||||||||
19 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 20 | -- | ||||||||||||||
20 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |