Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is the IP voltmeter approximately the same as battery voltage? | -- | System OK | Go to Step 2 |
2 | Connect a test lamp between the instrument panel cluster connector C3 terminal 14 and ground. Does the test lamp light? | -- | Go to Step 3 | Go to Step 5 |
3 | Connect a test lamp between the instrument panel cluster connector C3 terminal 13 and 14. Does the test lamp light? | -- | Go to Step 4 | Go to Step 8 |
4 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | System OK | -- |
5 | Connect a test lamp between connector C212 terminal F12 and ground. Does the test lamp light? | -- | Go to Step 6 | Go to Step 7 |
6 | Repair the open in CKT 21 (BRN), CKT 26 (BRN) between connector C212 terminal F12 and the instrument panel cluster. Is the repair complete? | -- | System OK | -- |
7 | Repair the open in CKT 371 (BRN), between connector C212 terminal F12 and the IP Fuse Block. Is the repair complete? | -- | System OK | -- |
8 | Repair the open in CKT 27 (BLK), between the instrument panel cluster and splice pack 3. Is the repair complete? | -- | System OK | -- |