GM Service Manual Online
For 1990-2009 cars only
Makes
🢒
Isuzu
🢒
2002
🢒
Isuzu T-Series (Truck Line C)
🢒
HVAC
🢒
Heating, Ventilation and Air Conditioning
🢒 Recirculation Door Replacement
Removal Procedure
Remove the instrument panel. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.
Remove the right heater module from the vehicle. Refer to
Heater/Vent Module Replacement
.
Remove the blower housing screws.
Remove the recirculation actuator. Refer to
Recirculation Actuator Replacement
.
Remove the evaporator cover from the blower module case.
Separate the blower module case.
Remove the recirculation doors (1, 2).
Installation Procedure
Install the recirculation doors (1, 2).
Assemble the blower module case.
Install the evaporator cover to the blower module case.
Install the recirculation actuator. Refer to
Recirculation Actuator Replacement
.
Install the blower housing screws.
Install the right heater module to the vehicle. Refer to
Heater/Vent Module Replacement
.
Install the instrument panel. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages and Console.