Removal Procedure
- Remove the lower inner window. Refer to
Front Side Door Window Replacement - Inner Lower
.
- Remove the trim panel. Refer to
Door Trim Panel Replacement
.
- Remove the water deflector.
- Remove the door window. Refer to
Door Window Replacement
.
- Remove the bolts from
the window regulator assembly.
- Remove the window regulator assembly.
Installation Procedure
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the window
regulator assembly with the bolts.
Tighten
Tighten the bolts to 9 N·m (79 lb in).
- Install the door window. Refer to
Door Window Replacement
.
- Install the water deflector.
- Install the trim panel. Refer to
Door Trim Panel Replacement
.
- Install the lower inner window. Refer to
Front Side Door Window Replacement - Inner Lower
.