Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Is the LOW WASHER FLUID level indicator on with the wash fluid level is OK? | -- | Go to Step 3 | Go to Step 2 |
2 | Is the LOW WASHER FLUID level indicator off with the washer fluid level low? | -- | Go to Step 8 | System OK |
3 |
Is the LOW WASHER FLUID level indicator on? | -- | Go to Step 5 | Go to Step 4 |
4 | Replace the windshield washer solvent level switch. Refer to Windshield Washer Solvent Container Replacement for service procedure. Is the repair complete? | -- | Go to Step 15 | -- |
5 |
Is the measured resistance same as the specified value? | ∞ | Go to Step 7 | Go to Step 6 |
6 | Repair short to ground in circuit 99. Is the repair complete? | -- | Go to Step 15 | -- |
7 | Replace the instrument cluster. Refer to Instrument Cluster Replacement for service procedure. Is the repair complete? | -- | Go to Step 15 | -- |
8 |
Is the LOW WASHER FLUID level indicator on? | -- | Go to Step 9 | Go to Step 12 |
9 |
Is the LOW WASHER FLUID level indicator on? | -- | Go to Step 10 | Go to Step 11 |
10 | Replace the windshield washer solvent level switch. Refer to Windshield Washer Solvent Container Replacement for service procedure. Is the repair complete? | -- | Go to Step 15 | -- |
11 | Repair poor connection or open in circuit 1250 between the windshield washer solvent level switch terminal B and G102. Is the repair complete? | -- | Go to Step 15 | -- |
12 |
Is the measured resistance within the specified value? | Less than 3ohms | Go to Step 13 | Go to Step 14 |
13 | Replace the instrument cluster. Refer to Instrument Cluster Replacement for service procedure. Is the repair complete? | -- | Go to Step 15 | -- |
14 | Repair poor connection or open in circuit 99. Is the repair complete? | -- | Go to Step 15 | -- |
15 |
Are there any instrument cluster DTCs present? | -- | System OK |