Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: In order to avoid misdiagnosis, set the J 39200 to zero before you take any measurements. | ||||
1 |
Are the resistance readings within specifications? | -- | Go to Step 3 | Go to Step 2 |
2 | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Gage Sensor Replacement . Has the repair been made and the system rechecked? | -- | System OK | -- |
3 | Replace the driver information display. Refer to Driver Information Center Replacement . Has the repair been completed and the system rechecked? | -- | System OK | -- |
Temperature | Resistance | |||
---|---|---|---|---|
Celsius | Fahrenheit | Minimum | Nominal | Maximum |
-35°C | -30°F | 206 629 ohms | 227 610 ohms | 250 588 ohms |
-18°C | 0°F | 79 825 ohms | 86 463 ohms | 93 878 ohms |
0°C | 32°F | 30 502 ohms | 32 645 ohms | 35 054 ohms |
25°C | 77°F | 9 456 ohms | 10 000 ohms | 10 574 ohms |
59°C | 138°F | 2 458 ohms | 2 579 ohms | 2 707 ohms |