Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The lock or unlock functions do not work through one of the door lock switches. However, the other door lock switch locks and unlocks the doors. | ||||
1 |
Does the test lamp light? | -- | Go to Step 2 | Go to Step 5 |
2 | While observing the door locks, connect a 10A fuse jumper between the inoperative door lock switch harness connector terminal A and terminal E. Do the door locks lock? | -- | Go to Step 3 | Go to Step 6 |
3 | While observing the door locks, connect a 10A fuse jumper between the inoperative door lock switch harness connector terminal D and terminal E. Do the door locks lock? | -- | Go to Step 4 | Go to Step 7 |
4 |
Is the repair complete? | -- | Go to Step 8 | -- |
5 | Repair the poor connection or the open in circuit 750. Is the repair complete? | -- | Go to Step 2 | -- |
6 | Repair the poor connection or the open in circuit 195. Is the repair complete? | -- | Go to Step 3 | -- |
7 | Repair the poor connection or the open in circuit 194. Is the repair complete? | -- | Go to Step 8 | -- |
8 |
Are there any BCM DTCs present? | -- |