Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect inoperative door lock actuator motor electrical connector.
- Connect a test lamp between the inoperative door lock harness
connector terminals A an B.
- Verify that the sliding door(s) are closed when diagnosing an
actuator motor on a sliding door.
- While observing the test lamp, press either door lock switch to
the UNLOCK position.
Does the test lamp flash once upon pressing UNLOCK?
| --
| Go to
Step 3
| Go to
Step
2
|
2
|
- Connect a test lamp between inoperative door lock harness connector
terminal A (terminal B on sliding door) and ground.
- While observing the test lamp, press either door lock switch to
the UNLOCK position.
Does the test lamp flash once upon pressing UNLOCK?
| --
| Go to
Step 4
| Go to
Step
5
|
3
| Replace the inoperative door lock actuator motor. Refer to
Front Side Door Lock Actuator Replacement
.
Is the repair complete?
| --
| Go to
Automatic Door Locks System Check
| --
|
4
|
• | Check door lock switch plate plungers and striker for good connection. |
• | If OK, repair poor connection or open in circuit 295. |
Is the repair complete?
| --
| Go to
Automatic Door Locks System Check
| --
|
5
| Repair poor connection or open in:
• | Driver's door lock: circuit 694. |
• | Passenger door locks: circuit 294. |
• | When diagnosing sliding doors actuator motors, check door lock
switch plate plungers and striker for good connection. |
Is the repair complete?
| --
| Go to
Automatic Door Locks System Check
| --
|