Electronic Traction Control Switch Replacement w/NW9
Removal Procedure
- Remove the trim plate bezel - IP
Cluster. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument Panel, Gages and Console.
- Remove the console accessory switch mount plate. Refer to
Front Floor Console Accessory Switch Mount Plate Replacement
in Instrument Panel, Gages and Console.
- Disconnect the electrical connector (2) from the traction
control switch.
- Remove the traction control switch mounting screw (1).
- Remove the traction control switch (3).
Installation Procedure
- Install the traction control switch (3).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the traction control switch mounting screw (1).
Tighten
Tighten the traction control mounting screw to 2 N·m (18 lb in).
- Connect the electrical connector (2) to the traction control
switch.
- Install the console accessory switch mount plate. Refer to
Front Floor Console Accessory Switch Mount Plate Replacement
in Instrument Panel, Gages and Console.
- Install the trim plate bezel - IP Cluster. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument
Panel, Gages and Console.