Removal Procedure
- Disconnect the negative
battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Remove the I/P cluster bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
.
- Remove the instrument
cluster bolts (1).
- Remove the instrument cluster (2).
Gently pull the cluster straight out to disconnect the electrical connector
(3).
Installation Procedure
- Install the instrument
cluster (2).
- Install the instrument cluster bolts (1).
Tighten
Tighten the instrument cluster bolts (1) to 2.2 N·m (19 lb in)
in sequence as shown.
- Install the I/P cluster bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
.
- Connect the negative battery
cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Synchronize the instrument panel cluster (IPC).
Instrument Panel Cluster Synchronization
Tools Required
Scan Tool
When installing a new I/P cluster it must be synchronized to the SIR
module. To synchronize the new cluster perform the following:
- Connect the Scan Tool
to the data link connector (DLC).
- On the Main Menu select the DIAGNOSTICS key (F0:).
- From the menu under F0: DIAGNOSTICS select the model year ((X)
1999).
- From the menu under (X) 1999 press the PASSENGER CAR key.
- Under the PASSENGER CAR menu select the BODY key (F1:).
- From the menu under F1: BODY select the F key.
- From the menu under F select either the (1) CHEVROLET or (2) PONTIAC
key.
- On the menu under the vehicle chosen select either the (K) 3.8L
V8 L36 or (G) 5.7L V8 LS1 key.
- On the menu under the engine chosen select the INSTRUMENT PANEL
CLUSTER (F1:) key.
- From the menu under F1: INSTRUMENT PANEL CLUSTER select the SPECIAL
FUNCTIONS (F2:) key.
- From the menu under F2: SPECIAL FUNCTIONS select the SYNCHRONIZE
IPC and SIR (F1:) key.
- When the F1: SYNCHRONIZE IPC and SIR is selected the following
will appear on the screen:
Do you want to synchronize IPC and SIR modules-Yes or No.
- Select the Yes key.
- The screen will display: IPC and SIR modules-Now synchronizing
modules.
This will remain until the procedure is complete.
- If the procedure is completed successfully the screen will display:
Module Synchronization Complete.
- If communication is lost with the SIR or IPC, the screen will
display: Loss of Communications with Vehicle-Check Diagnostics Link
Connector-Check Ignition (On/Off).
- Press the Exit key to return to the previous menu.