GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 220932  Size: SH

    Caution: When you are carrying an undeployed inflator module:

       • Do not carry the inflator module by the wires or connector on the inflator module
       • Make sure the bag opening points away from you
    When you are storing an undeployed inflator module, make sure the bag opening points away from the surface on which the inflator module rests. When you are storing a steering column, do not rest the column with the bag opening facing down and the column vertical. Provide free space for the air bag to expand in case of an accidental deployment. Otherwise, personal injury may result.

  1. Disable the SIR system. Refer to Disabling the SIR System .
  2. Remove the instrument panel carrier. Refer to Instrument Panel Carrier Replacement in Instrument Panel, Gauges and Console.

  3. Object Number: 220947  Size: SH
  4. Remove the inflatable restraint IP module bracket mounting fasteners (lower).
  5. Remove the inflatable restraint IP module bracket mounting fasteners (upper).
  6. Remove the inflatable restraint IP module bracket assembly from the IP carrier.

  7. Object Number: 220948  Size: SH
  8. Remove the inflatable restraint IP module mounting fasteners (3).
  9. Remove the inflatable restraint IP module (1) from the bracket (2).
  10. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Inflator Module Handling, Shipping, and Scrapping .

Installation Procedure


    Object Number: 220948  Size: SH
  1. Install the inflatable restraint IP module (1) to the bracket (2).
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the inflatable restraint IP module mounting fasteners (3).
  4. Tighten
    Tighten fasteners to 3.2 N·m (28 lb in).


    Object Number: 220947  Size: SH
  5. Install the inflatable restraint IP module bracket assembly to the IP carrier.
  6. Install the inflatable restraint IP module bracket mounting fasteners (upper).
  7. Tighten
    Tighten fasteners to 6 N·m (53 lb in).

  8. Install the inflatable restraint IP module bracket mounting fasteners (lower).
  9. Tighten
    Tighten fasteners to 2.8 N·m (25 lb in).


    Object Number: 220932  Size: SH
  10. Install the instrument panel carrier. Refer to Instrument Panel Carrier Replacement in Instrument Panel, Gauges and Console.
  11. Enable the SIR system. Refer to Enabling the SIR System .