An ignition voltage is supplied directly to the evaporative emission (EVAP) canister vent valve. The control module controls the EVAP vent valve by grounding the control circuit via an internal driver switch. The primary function of the driver is to supply ground for the controlled component. The control module monitors the status of the driver. If the control module detects an incorrect voltage for the commanded state of the driver, DTC P0449 sets.
• | The engine speed is more than 400 RPM. |
• | The system voltage is between 6-18 volts. |
• | The powertrain control module (PCM) detects that the commanded state of the driver and the actual state of the control circuit do not match. |
• | The above conditions are present for a minimum of 5 seconds. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
The numbers below refer to the step numbers on the diagnostic table.
A click should be heard or felt when the valve operates. Ensure that both the ON and the OFF states are commanded. Repeat the commands as necessary.
This step verifies that the PCM is providing ground to the EVAP vent valve.
This step tests if the EVAP vent valve control circuit is grounded.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Engine Controls Schematics | |||
1 | Did you perform the Diagnostic System Check-Engine Controls? | Go to Step 2 | |
Do you hear or feel a click from the EVAP vent valve when the valve is commanded ON and OFF? | Go to Step 3 | Go to Step 4 | |
3 |
Does this DTC fail this ignition? | Go to Step 4 | Go to Intermittent Conditions |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 13 |
Does the test lamp turn ON and OFF with each command? | Go to Step 9 | Go to Step 6 | |
Does the test lamp remain illuminated with each command? | Go to Step 8 | Go to Step 7 | |
7 | Test the control circuit of the EVAP vent solenoid for a short to voltage or for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 12 |
8 | Test the control circuit of the EVAP vent valve for a short to ground. Refer to Testing for Short to Ground and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 12 |
9 | Inspect for poor connections at the body pass-thru connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 10 |
10 |
Did you find and correct the condition? | Go to Step 16 | Go to Step 11 |
11 | Inspect for poor connections at the harness connector of the vent valve. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 14 |
12 | Inspect for poor connections at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 |
13 | Repair the ignition voltage circuit of the EVAP vent valve for an open or for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 16 | -- |
14 | Replace the EVAP vent valve. Refer to Evaporative Emission Canister Vent Solenoid Valve Replacement . Did you complete the replacement? | Go to Step 16 | -- |
15 | Replace the PCM. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | Go to Step 16 | -- |
16 |
Does the DTC run and pass? | Go to Step 17 | Go to Step 2 |
17 | With a scan tool, observe the stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | System OK |