Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
Important: : Cycle the ignition switch in order to verify the symptom before proceeding with this diagnostic procedure. | ||||||||
1 | Did you perform the Interior Lamps Diagnostic System Check? | -- | Go to Step 2 | |||||
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 4 | ||||
3 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 5 | ||||
4 | Test the following CKTs for an open:
Are all of the CKTs OK? | -- | Go to Step 6 | Go to Step 10 | ||||
5 | Test the following CKTs for an open:
Are all of the CKTs OK? | -- | Go to Step 6 | Go to Step 10 | ||||
6 | Replace the suspect door handle switch. Refer to Outside Handle and Lock Cylinder Replacement in Doors. Is the repair complete? | -- | -- | |||||
7 | Use a DMM to measure the resistance between connector C2 terminal G and connector C2 terminal F Is the resistance less than the specified value? | 10 ohms | Go to Step 8 | Go to Step 9 | ||||
8 | Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement in Instrument Panel, Gauges, and Console. Is the repair complete? | -- | -- | |||||
9 | Inspect CKT 156 and CKT 1732 for an open. Repair if necessary. Is the repair complete? | -- | -- | |||||
10 | Repair the faulty CKT. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |