Removal Procedure
- Remove the door trim panel. Refer to
Door Trim Panel Replacement
.
- Remove enough of the door
water deflector in order to access the lower window run channel. Refer to
Door Water Deflector Replacement
.
- Remove the bolt from the window run channel.
- Pull upward on the window run channel in order to disengage the
retainer (2).
- Remove the window run channel.
Installation Procedure
- Engage the retainer (2)
by pulling upward on the lower window run channel.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the bolt
to the window run channel.
Tighten
Tighten the bolt to 9 N·m (80 lb in).
- Install the door water deflector. Refer to
Door Water Deflector Replacement
.
- Install the door trim panel. Refer to
Door Trim Panel Replacement
.