The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | |||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information | ||||||||||||
2 |
Does the recirculation door move from the recirculation to the outside air position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||||||||||
3 |
Does the test lamp illuminate in both, recirculation and ambient air, positions? | Go to Step 5 | Go to Step 4 | ||||||||||||
4 | Test the recirculation door control A and B circuits of the recirculation actuator for an open, for a high resistance, for a short to ground, or for a short to voltage. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 6 | ||||||||||||
5 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? | Go to Step 12 | Go to Step 8 | ||||||||||||
Test the ignition 3 voltage circuits of the HVAC control assembly for an open or for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 7 | |||||||||||||
7 | Test the ground circuit of the HVAC control assembly for an open or for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 9 | ||||||||||||
8 | Inspect for bad connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 10 | ||||||||||||
9 | Inspect for bad connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 11 | ||||||||||||
10 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? | Go to Step 12 | -- | ||||||||||||
11 | Replace the HVAC Control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 12 | -- | ||||||||||||
12 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |