The numbers below refer to the step numbers on the diagnostic table.
When testing the circuit for a high resistance ensure to use the voltage drop test in the Circuit Testing procedure. If the circuit has more than a 0.5 volt drop when the starter is engaged, then there is a high resistance.
When testing the circuit for a high resistance ensure to use the voltage drop test in the Circuit Testing procedure. If the circuit has more than a 0.5 volt drop when the starter is engaged, then there is a high resistance. Ensure when testing the engine ground to battery to connect the engine ground lead to the base of the starter.
Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Starting and Charging Schematics | |||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||
2 | Turn the ignition to the START position. Did the starter solenoid click? | Go to Step 3 | |||||||
3 | Inspect the engine and belt drive system for mechanical binding, e.g. seized engine, seized generator. Does the engine move freely? | Go to Step 4 |
| ||||||
Test the battery positive cable between the battery and the starter solenoid for high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 5 | |||||||
Test the ground circuit between the battery and the engine for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 6 | |||||||
6 | Inspect for poor connections at the starter. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 8 | Go to Step 7 | ||||||
7 | Replace the starter. Refer to Starter Motor Replacement . Did you complete the replacement? | Go to Step 8 | -- | ||||||
8 | Operate the system for which the symptom occurred. Did you correct the condition? | System OK | Go to Step 2 |