Special Tools
KM-569-A
Plug Remover
Removal Procedure
- Position the transmission control lever into 4th gear.
- Remove the battery tray. Refer to
Battery Tray Replacement
.
- Release the selector lever.
Important: Do not remove the bolt.
- Loosen the bolt (1) for the relay point clamp.
- Disconnect the transmission rocker arm from the relay point bracket.
- Disconnect the 2 retaining clamps (1, 2) from the transmission rocker arm.
- Disconnect the selector lever from the universal joint.
• | Press in retaining spring (arrow) of the hollow pin (3). |
Installation Procedure
Important: Use new retaining clamps.
- Connect the transmission rocker arm to the relay point bracket.
Connect the 2 retaining clamps (1, 2) to the transmission rocker arm.
Important: Use a new hollow pin. Retaining spring (arrow) of hollow pin (3) must engage.
- Connect the selector lever to the universal joint.
Connect a hollow pin.
- Connect the selector lever to relay point.
Important: Do not tighten bolt (1) yet.
- Install battery tray. Refer to
Battery Tray Replacement
.
- Adjust the transmission shift linkage. Refer to
Selector Lever Link Adjustment
.
- For programming procedures, refer to
Control Module References
.