The number below refers to the step number on the diagnostic table.
Step | Action | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | |||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||||||
2 |
Does the recirculation door move from the recirculation to the outside air position? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | ||||||||||
3 |
Does the test lamp illuminate in both, recirculation and ambient air, positions? | Go to Step 5 | Go to Step 4 | ||||||||||
4 | Test the recirculation door control A and B circuits of the recirculation actuator for an open, for a high resistance, for a short to ground, or for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 12 | Go to Step 6 | ||||||||||
5 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? | Go to Step 12 | Go to Step 8 | ||||||||||
Test the ignition 3 voltage circuits of the HVAC control assembly for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 12 | Go to Step 7 | |||||||||||
7 | Test the ground circuit of the HVAC control assembly for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 12 | Go to Step 9 | ||||||||||
8 | Inspect for bad connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 12 | Go to Step 10 | ||||||||||
9 | Inspect for bad connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 12 | Go to Step 11 | ||||||||||
10 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? | Go to Step 12 | -- | ||||||||||
11 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 12 | -- | ||||||||||
12 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |