GM Service Manual Online
For 1990-2009 cars only

DTC Descriptor

DTC P2432 : Secondary Air Injection System Pressure Sensor A Circuit Low

Diagnostic Fault Information

Important: Always perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Pressure Sensor 5-Volt Reference Voltage

P2432

P2431

P2431

P2430, P2431

Pressure Sensor Signal

P2432

P2432

P2433

P2430, P2431

Pressure Sensor Low Reference

--

P2433

--

-

Pump Voltage Supply

P0411

P0411

P2444

--

Pump Ground

--

P0411

--

--

Solenoid Voltage Supply

P0411

P0411

P2440

--

Solenoid Ground

--

P0411

--

--

Pump Relay Coil Voltage Supply

P0411, P0418

P0411, P0418

--

--

Pump Relay Coil Control

P0418, P2444

P0411, P0418

P0418

--

Pump Relay Switch Supply

P0411

P0411

--

--

Solenoid Relay Coil Voltage Supply

P0411, P0412

P0411, P0412

--

--

Solenoid Relay Coil Control

P0412, P2440

P0411, P0412

P0412

--

Solenoid Relay Switch Supply

P0411

P0411

--

--

Typical Scan Tool Data

AIR Pressure Sensor

Circuit

Normal Range

Short to Ground

Open

Short to Voltage

Operating Conditions: Key ON, Engine OFF

5-Volt Reference Voltage

BARO

41 kPa

41 kPa

111 kPa

Pressure Sensor Signal

BARO

42 kPa

41 kPa

150 kPa

Low Reference

BARO

BARO

145 kPa

BARO

Circuit/System Description

The secondary air injection (AIR) system aids in the reduction of hydrocarbon emissions during a cold start. The system forces fresh filtered air into the exhaust stream in order to accelerate the catalyst operation. An electric air pump, the secondary AIR injection pump, provides filtered air on demand to the AIR control solenoid valve/pressure sensor assembly. The AIR control solenoid valve/pressure sensor assembly controls the flow of air from the AIR pump to the exhaust manifold. The AIR valve relay supplies the current needed to operate the AIR control solenoid valve/pressure sensor assembly. A pressure sensor is used to monitor the air flow from the AIR pump. The control module supplies the internal pressure sensor with a 5-volt reference, an electrical ground, and a signal circuit.

The AIR diagnostic uses 3 phases to test the AIR system:

  1. DTCs P0411 and P2430 run during Phase 1
  2. DTCs P2430 and P2440 run during Phase 2
  3. DTC P2444 runs during Phase 3

During phase 1, both the AIR pump and the solenoid valve are activated. Normal secondary air function occurs. Expected system pressure is 8-10 kPa above BARO.

During phase 2, only the AIR pump is activated. The solenoid valve is closed. Pressure sensor performance and solenoid valve deactivation are tested. Expected system pressure is 20-25 kPa above BARO.

During phase 3, neither the AIR pump nor the solenoid valve is activated. AIR pump deactivation is tested. Expected system pressure equals BARO.

In all 3 phases, testing is accomplished by comparing the measured pressure against the expected pressure. The control module can detect faults in the AIR pump, AIR control solenoid valve/pressure sensor assembly, and the exhaust check valve. The pressure sensor can also detect leaks and restrictions in the secondary AIR system plumbing.

Conditions for Running the DTC

    • DTCs P0606, P1635, P1639 are not set.
    • The ignition is ON or the engine is running.
    • DTC P2432 runs continuously when the above conditions are met.

Conditions for Setting the DTC

The pressure sensor signal is less than 0.2 volt for at least 12.5 seconds.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
    • The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

Conditions for Clearing the MIL/DTC

    • The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
    • A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
    • A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
    • Clear the MIL and the DTC with a scan tool.

Reference Information

Schematic Reference

Engine Controls Schematics

Connector End View Reference

    •  Engine Controls Connector End Views
    •  Engine Control Module Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

    •  Scan Tool Data List
    •  Scan Tool Data Definitions
    •  Scan Tool Output Controls

Circuit/System Verification

Engine running, observe that the AIR Pressure Sensor parameter approximately equals BARO.

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the AIR solenoid valve.
  2. Ignition OFF, test for less than 1 ohm of resistance between the low reference circuit terminal and ground.
  3. If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the control module.
  4. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal and ground.
  5. If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the control module.
    If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the control module.
  6. Verify the scan tool AIR Pressure Sensor parameter is less than 0.5 volts.
  7. If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the control module.
  8. Install a 3-amp fused jumper wire between the signal circuit terminal and the 5-volt reference circuit terminal. Verify the scan tool AIR Pressure Sensor parameter is greater than 4.9 volts.
  9. If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the control module.
  10. If all circuits test normal, test or replace the AIR solenoid valve.

Component Testing

Solenoid Valve

Apply fused battery voltage and ground to the solenoid and verify that the valve opens and closes completely as voltage is applied to and removed from the solenoid. Observe that the valve is not obstructed or leaking.

If the valve operates incorrectly, leaks, or is obstructed, remove the obstruction or replace the valve.

Repair Instructions

    •  Secondary Air Injection Pump Replacement
    •  Secondary Air Injection Pump Inlet Hose/Duct Replacement
    •  Secondary Air Injection Pump Outlet Pipe/Hose Replacement
    •  Secondary Air Injection Check Valve Replacement
    •  Control Module References for control module replacement, setup, and programming

Repair Verification

With the engine RUNNING, enable the AIR pump with a scan tool and observe that the AIR Pressure Sensor parameter equals approximately 20-25 kPa above BARO.