Charging System Test Solstice
Diagnostic Instructions
Reference Information
Description and Operation
Charging System Description and Operation
Electrical Information Reference
Testing for Intermittent Conditions and Poor Connections
Circuit/System Verification
Engine ON, observe the charge indicator on the instrument panel cluster (IPC) or message in the driver information center (DIC). The charge indicator on the IPC should be turned OFF and the DIC should not display charging system message.
⇒ | If the charge indicator is on the IPC or a charging system message is displayed on the DIC, refer to Circuit/System Testing. |
Circuit/System Testing
- Ignition ON, verify that no generator or battery current sensor DTCs are set that would cause a charging system concern.
- Ignition OFF, measure the voltage across the battery terminals. The voltage should read 12.0 volts or greater at room temperature.
- Connect a carbon pile tester to the battery.
- Start the engine and increase the engine speed to 2,500 RPM. Observe the voltage reading on the tester. The voltage should read between 12.6 - 15.0 volts.
⇒ | If not within specified range, replace the generator. |
- Adjust the carbon pile tester to the specified load test output value, refer to
Generator Usage
.
⇒ | If not within specified value, replace the generator. |
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.
Generator Replacement
Charging System Test SKY
Diagnostic Instructions
Reference Information
Description and Operation
Charging System Description and Operation
Electrical Information Reference
Testing for Intermittent Conditions and Poor Connections
Special Tools
SA9154Z-A
Starting System Tester
Circuit/System Verification
Engine ON, observe the charge indicator on the instrument panel cluster (IPC) or message in the driver information center (DIC). The charge indicator on the IPC should be turned OFF and the DIC should not display charging system message.
⇒ | If the charge indicator is on the IPC or a charging system message is displayed on the DIC, refer to Circuit/System Testing. |
Circuit/System Testing
- Ignition ON, verify that no generator or battery current sensor DTCs are set that would cause a charging system concern.
- Engine OFF, connect the
SA9154Z-A
Starting System Tester red lead to the battery positive terminal and the grey lead to the output circuit of the generator.
- Engine ON, turn ON the
SA9154Z-A
Starting System Tester. Turn all vehicle accessories OFF and follow all the prompts.
- Press the CHARGING SYSTEM TEST button. The display should read 13.0 - 15.5 volts.
⇒ | If not within specified range, replace the generator. |
- Is the generator output current greater than or equal to the load test output value given in
Generator Usage
?
⇒ | If not within specified value, replace the generator. |
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.
Generator Replacement