• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
5-Volt Reference | P0557 | P0557 | P0557 | P0558 | P0556 |
Brake Booster Vacuum Sensor Signal | P0557 | P0557 | P0557 | P0558 | P0556 |
Low Reference | -- | P0557 | P0558 | -- | P0556 |
The power brake booster vacuum sensor monitors the vacuum pressure in the brake booster. The ECM compares the readings of the engine vacuum with the brake booster vacuum.
• | Engine is running and vehicle speed is above 40 km/h (25 mph). |
• | No TPS sensor DTCs are present. |
• | The transmission is in drive. |
Engine running.
• | Engine is running. |
• | The ECM detects the vacuum level between the engine and brake booster is greater than 6kPa. |
The ECM detects a short to ground or open in either the sensor signal circuit or the brake booster vacuum sensor.
The ECM detects an open with the sensor ground or a short to voltage in either the signal circuit or the brake booster vacuum sensor.
DTC P0556, P0557, or P0558 are a type B DTC.
DTC P0556, P0557, or P0558 are a type B DTC.
Antilock Brake System Schematics
Antilock Brake System Connector End Views
Hill Hold Control Description and Operation
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit terminal for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |