• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Evaporator Sensor Signal | B3933 14 | B3933 14, B3933 13 | B3933 13 | -- |
Evaporator Low Reference Signal | -- | 1 | -- | -- |
1. A/C Compressor Will Not Engage |
The HVAC control module supplies the evaporator temperature sensor with a low reference circuit and 5-volt signal circuit. The HVAC control module determines the voltage drop across the sensor, which is proportional to temperature. When the refrigerant temperature is low the sensor resistance and voltage signal are high.
Ignition ON.
The HVAC control module detects the evaporator air temperature sensor signal circuit is less than -40°C (-40°F) or more than 120°C (248°F) for more than 15 seconds.
The default value of 74°C (165.2°F) will be substituted for the evaporator.
• | The DTC will become history if the HVAC control module no longer detects a failure. |
• | The history DTC will clear after 100 fault-free ignition cycles. |
Control Module References for scan tool information
Ignition ON, observe the scan tool A/C Evaporator Temperature Sensor parameter. The reading should be between -35 and +98°C (-39 and +208°F) and change with evaporator air temperature changes.
⇒ | If greater than the specified range, test the low reference circuit terminal for an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If not within the specified range, replace the sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module replacement, setup, and programming |