GM Service Manual Online
For 1990-2009 cars only
Makes
🢒
Saturn
🢒
2009
🢒
VUE - AWD
🢒
Hybrid
🢒
Hybrid Cooling - HP5
🢒 Drive Motor Generator Control Module Coolant Pump Replacement
Drive Motor Generator Control Module Coolant Pump Replacement Upper
Special Tools
J 38185
Hose Clamp Pliers
Removal Procedure
Drain the generator control module cooling system. Refer to
Generator Control Module Cooling System Draining and Filling
Remove the generator control module coolant pump hose - pump to radiator inlet. Refer to
Generator Control Module Coolant Pump Hose Replacement - Pump to Radiator Inlet
Remove the generator control module coolant pump hose. Refer to
Generator Control Module Coolant Pump Hose Replacement
Disconnect the electrical connectors from the drive motor generator control module coolant pumps.
Remove the drive motor generator control module coolant pump bolts (1).
Remove the drive motor generator control module coolant pump hose assembly (2) from the vehicle.
Remove the drive motor generator control module coolant pump hose clamp (1) using
J 38185
Hose Clamp Pliers .
Remove the drive motor generator control module coolant upper pump (2).
Installation Procedure
Install the drive motor generator control module coolant upper pump (2).
Install the drive motor generator control module coolant pump hose clamp (1) using
J 38185
Hose Clamp Pliers .
Install the drive motor generator control module coolant pump hose assembly (2) from the vehicle.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the drive motor generator control module coolant pump bolts (1) and tighten to
7.5 N·m (66 lb in)
.
Connect the electrical connectors to the drive motor generator control module coolant pumps.
Install the generator control module coolant pump hose. Refer to
Generator Control Module Coolant Pump Hose Replacement
Install the generator control module coolant pump hose - pump to radiator inlet. Refer to
Generator Control Module Coolant Pump Hose Replacement - Pump to Radiator Inlet
Fill the generator control module cooling system. Refer to
Generator Control Module Cooling System Draining and Filling
Drive Motor Generator Control Module Coolant Pump Replacement Lower
Special Tools
J 38185
Hose Clamp Pliers
Removal Procedure
Drain the generator control module cooling system. Refer to
Generator Control Module Cooling System Draining and Filling
Remove the generator control module coolant pump hose - pump to radiator inlet. Refer to
Generator Control Module Coolant Pump Hose Replacement - Pump to Radiator Inlet
Remove the generator control module coolant pump hose. Refer to
Generator Control Module Coolant Pump Hose Replacement
Disconnect the electrical connectors from the drive motor generator control module coolant pumps.
Remove the drive motor generator control module coolant pump bolts (1).
Remove the drive motor generator control module coolant pump hose assembly (2) from the vehicle.
Remove the drive motor generator control module coolant pump hose clamp (1) using
J 38185
Hose Clamp Pliers .
Remove the drive motor generator control module coolant lower pump (2).
Installation Procedure
Install the drive motor generator control module coolant lower pump (2).
Install the drive motor generator control module coolant pump hose clamp (1) using
J 38185
Hose Clamp Pliers .
Install the drive motor generator control module coolant pump hose assembly (2) from the vehicle.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the drive motor generator control module coolant pump bolts (1) and tighten to
7.5 N·m (66 lb in)
.
Connect the electrical connectors to the drive motor generator control module coolant pumps.
Install the generator control module coolant pump hose. Refer to
Generator Control Module Coolant Pump Hose Replacement
Install the generator control module coolant pump hose - pump to radiator inlet. Refer to
Generator Control Module Coolant Pump Hose Replacement - Pump to Radiator Inlet
Fill the generator control module cooling system. Refer to
Generator Control Module Cooling System Draining and Filling