Adjustment Procedure
- Remove the center trim bezel. Refer to
Instrument Panel Accessory Bezel Replacement
in Instrument Panel, Gages and Console.
- Remove the temperature cable from the HVAC control module.
- Center the HVAC module temperature door
by aligning the cable lug of the temperature control cable with the center point of
the detent spring. Detent spring force should hold the temperature door in the desired
position.
- Center the temperature cable knob by inserting
the assembly alignment tab into the centering slot of the temperature knob shaft.
- Install the temperature cable to the HVAC control module by aligning the retention
tabs and the temperature knob shaft and snapping into place.
- Install the center trim bezel. Refer to
Instrument Panel Accessory Bezel Replacement
in Instrument Panel, Gages and Console.