Important: Use care when removing the control valve body assembly. The control solenoid valve assembly and the control valve body assembly may separate.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the 3 silver bolts to 8 N·m (6 lb ft) in the sequence shown.
Tighten
Tighten the 15 black bolts in three separate steps in the sequence shown.
4.1. | Tighten to 5 N·m (4 lb ft) |
4.2. | Tighten to 10 N·m (7 lb ft) |
4.3. | Tighten to 15 N·m (11 lb ft) |
Important: Note the orientation of the manual valve before connecting the manual valve link assembly.
Tighten