Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 |
Is air flowing out of any of the outlets? | -- | Go to Step 7 | Go to Step 2 | ||||||||
2 |
Is air flowing through the vent outlets at the ambient temperature, and is no air flowing through the heater, the defroster, and the side window defroster outlets? | -- | Go to Step 3 | Go to Step 7 | ||||||||
3 |
Is hot air flowing through the heater outlet at the blower hi speed, is minimum hot air flowing through the defroster and through the side window defroster outlets, and is no air flowing through the vent outlets? | -- | Go to Step 4 | Go to Step 7 | ||||||||
4 |
Is hot air flowing through the defroster outlet at blower hi speed, is minimum hot air flowing through the heater and through the side window defroster outlets, and is no air flowing through the vent outlets? | -- | Go to Step 5 | Go to Step 7 | ||||||||
5 |
Is the door travel and effort correct? | -- | Go to Step 6 | Go to Step 8 | ||||||||
6 | Inspect the control cable(s) travel by moving the corresponding control at the heater control unit. Is the control cable travel correct? | -- | Go to Step 9 | Go to Step 10 | ||||||||
7 | Repair the affected control cable(s) as necessary. Refer to Temperature Control Cable Adjustment , Vent Control Cable Adjustment or Mode Control Cable Adjustment . Is the repair complete? | -- | Go to Step 11 | -- | ||||||||
8 | Repair the affected door at the heater case. Is the repair complete? | -- | Go to Step 11 | -- | ||||||||
9 | Reinstall the control cable(s). Is the repair complete? | -- | Go to Step 11 | -- | ||||||||
10 | Repair the control cable(s) attachment at the heater control unit. Is the repair complete? | -- | Go to Step 11 | -- | ||||||||
11 | Perform the functional test. Refer to Functional Check Is the repair complete? | -- | -- |