Step | Action | Value(s) | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:: Excessive moisture in the vehicle could affect system performance, this could be caused by:
Important:: The A/C compressor will not operate (to reduce humidity) in ambient temperatures below 5°C (41°F). | ||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check | ||||||||||||
2 |
Does the scan tool display any DTCs? | -- | Go to DTC Table | Go to Step 3 | ||||||||||||
3 |
Does the scan tool indicate that the Commanded Blower data parameter is greater than the specified range? | 100% | Go to Step 4 | |||||||||||||
4 |
Does the airflow change discharge locations? | -- | Go to Step 5 | Go to Air Delivery Improper | ||||||||||||
5 |
Important:: Indicated outside air temperature must be above 5°C (41°F).
Does the A/C compressor operate? | -- | Go to Step 6 | |||||||||||||
6 | With a scan tool, observe the ECT data parameter in the powertrain control module data list. Does the scan tool indicate that the ECT data parameter is within the specified range? | 87°C to 98°C (188°F to 208°F) | Go to Step 7 | Go to Symptoms in Engine Cooling | ||||||||||||
7 | Is the defrost airflow warm? | -- | Go to Step 8 | Go to Heating Insufficient | ||||||||||||
8 | Is the defrost airflow sufficient and is the left defrost airflow similar to the right defrost airflow at the defroster grille and side window outlet? | -- | Go to Step 11 | Go to Step 9 | ||||||||||||
9 |
Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 10 | ||||||||||||
10 | Inspect the mode door actuator for binding or mechanical failure. Refer to Mode Actuator Replacement . Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 11 | ||||||||||||
11 |
Does the system operate properly? | -- | System OK | Go to Symptoms | ||||||||||||
12 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |