Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the blower motor operate in any of the speed positions? | Go to Blower Motor Malfunction | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 14 | Go to Step 4 |
4 | Probe the supply voltage circuit of the blower motor with a test lamp that is connected to a good ground. Does the test lamp illuminate? | Go to Step 9 | Go to Step 5 |
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 17 |
6 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 8 |
7 | Test the blower motor supply voltage circuit for an open, short to ground or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 13 |
8 | Test the blower motor relay control circuit for an open, short to voltage or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 16 |
9 |
Does the test lamp illuminate? | Go to Step 11 | Go to Step 10 |
10 | Test the blower motor speed control circuit for an open, short to ground, short to voltage or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 16 |
11 | Test the ground circuit of the blower motor control processor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 12 |
12 | Test the ground circuit between the blower motor and the blower motor control processor for an open, short to voltage or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 15 |
13 | Inspect for poor connections at the harness connector of the blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 18 |
14 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 19 |
15 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 20 |
16 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 22 | Go to Step 21 |
17 | Repair the battery positive voltage circuit of the blower motor relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 22 | -- |
18 | Replace the blower motor relay. Did you complete the replacement? | Go to Step 22 | -- |
19 | Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 22 | -- |
20 | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? | Go to Step 22 | -- |
21 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 22 | -- |
22 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |