Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Were you sent here from the Cooling Insufficient, A/C System diagnostic table? | -- | ||
2 | Visually inspect for restricted air flow at the condenser. Is the air flow through the condenser restricted? | -- | ||
3 | Repair the air flow restriction condition or replace the condenser, if damaged. Refer to Condenser Replacement . Is the repair complete? | -- | -- | |
4 | Start the engine and turn the A/C ON. Are the cooling fan(s) ON and operating properly? | -- | ||
5 | Repair the cooling fan operation fault. Refer to Electric Cooling Fan Diagnosis in Engine Controls - 3.1L. Is the repair complete? | -- | -- | |
6 |
Is the temperature the same before and after the orifice? | -- | ||
7 | Turn the engine OFF. Replace the damaged/faulty expansion (orifice) tube (orifice opening too large and/or the O-ring is damaged or missing). Refer to Expansion (Orifice) Tube Replacement . Is the repair complete? | -- | -- | |
8 |
Is the repair complete? | -- | -- | |
9 |
Are the readings within the specified ranges? | -- | ||
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | Go to Symptoms in HVAC Systems - Manual | |
11 |
Is the action complete? | -- | System OK | -- |