The AF ECU and the gasoline control module (VCM/PCM or ECM) are connected by the natural gas operation (NGO) enable circuit. In order for the engine to switch-over to CNG operation the gasoline control module must be commanded to disable the gasoline fuel injectors, switch to a different ignition spark calibration and disable some of the gasoline control module DTCs. The AF ECU performs the switch-over command by grounding the NGO enable circuit when CNG operation is desired.
This vehicles primary fuel source is compressed natural gas (CNG). The vehicle will only switch-over to gasoline operation if one of the following conditions is present:
• | The fuel pressure sensor (FPS) indicates the CNG tank is empty. |
• | A wide-open mixture control valve (MCV) is detected. |
• | A system fault is detected by the AF ECU. |
• | Engine crank time exceeds about 8 seconds. |
• | Every 100th start and also when the coolant temperature is below 10°F (-12°C) the vehicle will start and run briefly on gasoline. A switch-over to CNG will occur only during a decel condition. |
This diagnostic information should be utilized only if the concern of the vehicle operator can be duplicated. An unwanted switch may occur only during specific vehicle operation. An example follows:
At the same moment that the HPL is opened the AF ECU monitors the fuel pressure sensor.
If the LPL is still leaking the CNG pressure cannot build within the system and low fuel pressure is observed by the AF ECU.
Detecting the low fuel pressure in the system the AF ECU performs a switch-over to gasoline.
The customer concern would be an intermittent unwanted switch to gasoline with no DTCs stored.
If an unwanted switch only occurs during certain driving conditions perform the Fuel System Diagnosis and verify that fuel pressure can be maintained.
Fault Not Present indicates the condition that caused the concern is intermittent and not currently present. Refer to Intermittent Conditions Symptom diagnosis for additional information. If any additional concerns were observed return to the AF Powertrain OBD System Check.
The number(s) below refer to the step number(s) on the diagnostic table.
The AF Powertrain OBD System Check MUST be performed before proceeding with this diagnostic table. Failure to perform the OBD System Check will result in mis-diagnosis.
This step checks if the AF ECU has commanded the gasoline control module (using the NGO Enable circuit) to start on CNG.
The NGO Enable Output parameter is the commanded state of the NGO Enable circuit from the AF ECU. The NGO Enable Input parameter is the monitored state of the NGO Enable circuit from the GASOLINE control module (VCM/PCM or ECM).
This step checks if the FIL is illuminated during CNG operation. The FIL should illuminate only during gasoline operation.
This step checks if the FPS is monitoring adequate fuel tank pressure for the vehicle to start on CNG.
This step checks the ability of the AF ECU to command Natural Gas Operation (NGO) and the gasoline control modules ability to monitor the command.
This step indicates all the possibilities that cause a switch-over to gasoline operation.
This step checks the ignition system of the vehicle for proper operation. A vehicle that operates correctly on gasoline but not on CNG may have a faulty ignition system.
Performing the AF Fuel System Diagnosis checks the basic AF fuel system for proper pressures and lock-off solenoid operation.
A fuel system that is unable to retain fuel pressure after the ignition is turned OFF may cause an Unwanted Switch to Gasoline. The AF ECU commands the HPL open for about 1 second every time the ignition is turned ON. If the fuel line system leaks during ignition OFF the next ignition ON prime pulse will usually recharge the fuel lines and the FPS. A 'sluggish' HPL may not open during the 1 second prime pulse but will open when commanded with the scan tool.
This step checks for proper fuel pressure sensor operation.
This step checks for an inoperative HPL. After connecting to a CNG dispensing station the CNG fuel lines, the FPS and the fuel tank will be charged by the station. The CNG fuel pressure in the lines and the FPS will quickly drop if the engine is operating on CNG but the HPL fails to open.
This step checks for proper operation of the NGO Enable circuit and the gasoline control module.
This step checks for a leaking fuel system with a 'sluggish' HPL.
Step | Action | Value(s) | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Were you sent here from the AF Powertrain On-Board Diagnostic (OBD) System Check? | -- | Go to Alternative Fuels (AF) Powertrain On Board (OBD) System Check | ||||||||||||||||||||||
Do the data parameters indicate that Natural Gas Operation is enabled? | -- | |||||||||||||||||||||||
Observe the fuel indicator lamp (FIL) located in the fuel gauge select switch button with the vehicle running. Is the FIL illuminated? | -- | Go to Fuel Gauge Selector Switch/Fuel Indicator Lamp Diagnosis | ||||||||||||||||||||||
4 | The fault is not present. Refer to Diagnostic Aids. Is their a system operation concern? | -- | Go to Alternative Fuels (AF) Powertrain On Board (OBD) System Check | System OK | ||||||||||||||||||||
Using the scan tool communicate with the AF ECU and observe the Fuel Pressure Sensor data parameter. Does the Fuel Pressure Sensor indicate pressure greater than the value specified? | 8274 kPa (1200 psi) | |||||||||||||||||||||||
Does the parameter indicate that Natural Gas Operation is enabled? | -- | |||||||||||||||||||||||
Was a problem found and repaired? | -- | |||||||||||||||||||||||
Important: A higher secondary ignition voltage is required to operate the engine on Alternative Fuel than on gasoline. A vehicle that operates normally on gasoline does not indicate a fully functional ignition system. Important: Accurate CKP operation is required for Alternative Fuel operation. Check the CKP sensor on any vehicle that starts and immediately stalls.
Was a repair necessary? | -- | |||||||||||||||||||||||
Perform the Fuel System Diagnosis procedure and return to this step. Was a repair required in the AF Fuel System Diagnosis? | -- | |||||||||||||||||||||||
Does the FPS fuel pressure increase greater than the value specified when the HPL is opened? | 8274 kPa (1200 psi) | |||||||||||||||||||||||
Important: Before proceeding with FPS diagnosis ensure that the manual lock-down screw of the HPL manual shut-off fitting is open by rotating the allen screw counter-clockwise until fully seated.
Is the FPS accurately indicating fuel pressure? | -- | |||||||||||||||||||||||
Does the FPS data parameter ever drop below the pressure value specified? | 8274 kPa (1200 psi) | |||||||||||||||||||||||
If the jumper fuse opens repair the short to voltage on the NGO Enable circuit. Does the data parameter indicate that Natural Gas Operation is enabled? | -- | |||||||||||||||||||||||
14 |
Was a repair necessary? | -- | ||||||||||||||||||||||
Is the repair complete? | -- | -- | ||||||||||||||||||||||
16 |
Was a repair necessary? | -- | ||||||||||||||||||||||
17 |
Important: The following control module replacement procedures must all be completed before attempting to operate the vehicle.
Important: In order to perform the variation learn procedure a switch-over to gasoline operation is necessary. Remove the CNG 20 amp fuse in order to perform the switch-over. All of the above procedures are located in the C/K Truck Service manual. Is the replacement complete? | -- | -- | |||||||||||||||||||||
18 |
Is the replacement complete? | -- | -- | |||||||||||||||||||||
19 | Replace the high pressure lock-off (HPL solenoid. Refer to High Pressure Lock-Off Solenoid Replacement . Is the replacement complete? | -- | -- | |||||||||||||||||||||
20 | Replace the GMS/MCV. Refer to Gas Mass Sensor/Mixture Control Valve and Mounting Bracket Replacement . Is the replacement complete? | -- | -- | |||||||||||||||||||||
21 |
Does the vehicle operate on CNG with normal driveability, no FIL/MIL illumination and no stored DTCs? | -- | System OK | Go to Alternative Fuels (AF) Powertrain On Board (OBD) System Check |