Step | Action | Normal Result(s) | Abnormal Result(s)* |
---|---|---|---|
1 |
| The ALC compressor motor turns on and runs continuously for up to 10 minutes before shutting off. | |
2 | Depress the core of the inflator fill valve. | High pressure air is available at the inflator fill valve. | |
3 | Depress the load leveling inflator switch OFF. | The ALC compressor motor turns off. | |
4 | Place a 250--300 lb load to the rear of the vehicle. |
| Automatic Level Control Compressor Motor Does Not Activate |
5 | Remove the load from the rear of the vehicle. |
| Automatic Level Control System Does Not Vent to Lower Vehicle |
6 |
| No action from Load Leveling Pump. | |
7 | No abnormal results were found while performing System Check. | The system is OK. | The customer complaint is not resolved. Go to Intermittents and Poor Connections Diagnosis . |
* Refer to the appropriate symptom diagnostic table for the applicable abnormal result. |