Step | Action | Normal Result(s) | Abnormal Result(s)* | ||||||
---|---|---|---|---|---|---|---|---|---|
1 | Move the ignition switch from the OFF position to the RUN position. | Battery indicator lamp turns ON, voltmeter gage reads between 12-14 volts. | |||||||
2 | Move the Ignition Switch to the START position and then release. | The engine starts, the voltage gage reads between 13-16 volts, the battery indicator lamp turns OFF. | |||||||
3 | Run the engine at idle while observing the voltmeter gage and the battery indicator lamp. | Voltmeter gage holdssteady between 13-16 volts and the battery indicator lamp is OFF. | |||||||
4 |
| Voltmeter gage holds steady between 13-16 volts and the battery indicator lamp is OFF. | |||||||
* Refer to the appropriate symptom diagnostic table for the applicable abnormal result. |