Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Perform the starting system check. Refer to Starting System Check . Does the solenoid click and the engine crank? | -- | System OK | Go to Step 2 | ||||||||
2 |
Does the solenoid click and the engine crank? | -- | System OK | Go to Step 3 | ||||||||
3 | Does the solenoid click, but the engine does not crank? | -- | Go to Step 4 | |||||||||
4 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 | ||||||||
5 | Replace or repair the starter motor. Refer to Starter Motor Overhaul . Is the repair complete? | -- | System OK | -- | ||||||||
6 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 | ||||||||
7 | Locate and repair the open in CKT 6 (PPL) or CKT 2 (RED) between the starter relay and the starter solenoid. Is the repair complete? | -- | System OK | -- | ||||||||
8 | Connect a test lamp from CKT 2 (RED) at the starter relay terminal 24 to chassis ground. Does the test lamp light? | -- | Go to Step 10 | Go to Step 9 | ||||||||
9 | Locate and repair the open in CKT 2 (RED) or CKT 4 (RED) or CKT 32 (BLU) (the fusible link) between the starter relay and the starter motor. Is the repair complete? | -- | System OK | -- | ||||||||
10 |
Does the test lamp light? | -- | Go to Step 11 | Go to Step 14 | ||||||||
11 |
Does the engine crank? | -- | Go to Step 12 | Go to Step 13 | ||||||||
12 | Locate and repair the open in CKT 150 (BLK) between the starter relay and G107. Is the repair complete? | -- | System OK | -- | ||||||||
13 | Replace the starter relay. Refer to Starter Motor Relay Replacement . Is the repair complete? | -- | System OK | -- | ||||||||
14 |
Does the test lamp light? | -- | Go to Step 15 | Go to Step 16 | ||||||||
15 | Locate and repair the open in CKT 434 (ORN/BLK) between the neutral switch and the starter relay. Is the repair complete? | -- | System OK | -- | ||||||||
16 |
Does the test lamp light? | -- | Go to Step 17 | Go to Step 20 | ||||||||
17 | Inspect the neutral switch for proper adjustment. Is an adjustment necessary? | -- | Go to Step 18 | Go to Step 19 | ||||||||
18 | Adjust the neutral switch as necessary. Does the starter solenoid click and the engine crank? | -- | System OK | Go to Step 19 | ||||||||
19 | Replace the neutral switch. Is the repair complete? | -- | System OK | -- | ||||||||
20 |
Does the test lamp light? | -- | Go to Step 21 | Go to Step 22 | ||||||||
21 | Locate and repair the open in CKT 33 (YEL) or CKT 5 (YEL) or CKT 806 (PPL) between the ignition switch and the neutral position switch. Is the repair complete? | -- | System OK | -- | ||||||||
22 | Connect a test lamp from CKT 30 (WHT/RED) at terminal B1 of the ignition switch to chassis ground. Does the test lamp light? | -- | Go to Step 23 | Go to Step 24 | ||||||||
23 | Replace the ignition switch. Is the repair complete? | -- | System OK | -- | ||||||||
24 | Locate and repair the open in CKT 30 (WHT/RED) between the ignition switch and the IP fuse block. Is the repair complete? | -- | System OK | -- |