Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the voltmeter indicate battery voltage? | -- | Go to Step 2 | Go to Step 4 |
2 |
Does the voltmeter indicate battery voltage? | -- | Go to Step 3 | Go to Step 5 |
3 | Repair the short to the battery in CKT 15, CKT 483 or 603 (YEL/RED) between the instrument cluster and the multifunction alarm module terminal B2. Is the repair complete? | -- | System OK | -- |
4 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | System OK | -- |
5 | Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement . Is the repair complete? | -- | System OK | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Backprobe the low coolant probe connector with a J 39200 DMM from terminal B to B+. Is the voltage less than the specified value? | 10.0 V | Go to Step 2 | Go to Step 3 |
2 | Locate and repair the open in CKT 150 (BLK) between the low coolant probe and G 107. Is the repair complete? | -- | System OK | -- |
3 |
Does the lamp turn on? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the low coolant probe. Refer to Coolant Level Sensor Replacement . Is the repair complete? | -- | System OK | -- |
5 |
Is the voltage less than the specified value? | 10.0 V | Go to Step 6 | Go to Step 7 |
6 | Locate and repair the open in CKT 1478, CKT 481 or CKT 601 (LT GRN) between the low coolant probe and the multifunction alarm module. Is the repair complete? | -- | System OK | -- |
7 |
Does the test lamp light? | -- | Go to Step 8 | Go to Step 9 |
8 | Locate and repair the open in CKT 15, CKT 603 or CKT 483 (YEL/RED) between the instrument cluster and the multifunction alarm module. Is the repair complete? | -- | System OK | -- |
9 | Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement . Is the repair complete? | -- | System OK | -- |