Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the ALC System Check? | -- | Go to Step 2 | |||||||
2 | Does the compressor motor run for 3-5 seconds (air replenishment cycle) approximately every minute? | -- | Go to Step 17 | Go to Step 3 | ||||||
3 |
Did the test light illuminate? | -- | Go to Step 4 | Go to Step 11 | ||||||
4 | Test for a short to ground in CKT 320. Did you find the condition? | -- | Go to Step 5 | Go to Step 6 | ||||||
5 | Repair the short to ground in CKT 320. Did you complete the repair? | -- | -- | |||||||
6 | Test for a short to ground in CKT 321. Did you find the condition? | -- | Go to Step 7 | Go to Step 8 | ||||||
7 | Repair a short to ground in CKT 321. Did you complete the repair? | -- | -- | |||||||
8 | Using a test light between B+ and the air inflator relay connector terminal A. Did the test light illuminate? | -- | Go to Step 9 | Go to Step 10 | ||||||
9 | Replace the air inflator relay. Refer to Automatic Level Control Relay Replacement for long wheel base with HVAC, or Automatic Level Control Relay Replacement for long wheel base without HVAC, or Automatic Level Control Relay Replacement for short wheel base. Did you complete the repair? | -- | -- | |||||||
10 | Replace the inflator air switch. Refer to Automatic Level Control Inflator Air Switch Replacement for long wheel base with HVAC, or Automatic Level Control Inflator Air Switch Replacement for long wheel base without HVAC, or Automatic Level Control Inflator Air Switch Replacement for short wheel base. Did you complete the repair? | -- | -- | |||||||
11 |
Did the test light illuminate? | -- | Go to Step 13 | Go to Step 12 | ||||||
12 | Replace the auto level control sensor. Refer to Automatic Level Control Sensor Link Replacement . Did you complete the repair? | -- | -- | |||||||
13 | Rotate the height sensor arm to 45° above horizontal. Did the test light illuminate? | -- | Go to Step 12 | Go to Step 14 | ||||||
14 |
Did the test light turn OFF? | -- | Go to Step 15 | Go to Step 12 | ||||||
15 | Rotate the height sensor arm to 45° below horizontal. Did the test light turn OFF? | -- | Go to Step 16 | Go to Step 12 | ||||||
16 |
Does the test lamp illuminate? | -- | Go to Step 17 | Go to Step 18 | ||||||
17 | Replace the auto level control air compressor relay. Refer to Air Compressor Relay Replacement . Did you complete the repair? | -- | -- | |||||||
18 | Replace the auto level control air compressor. Refer to Air Compressor Replacement . Did you complete the repair? | -- | -- |