The numbers below refer to the step numbers on the diagnostic table.
To observe the recirculation actuator, lower the glove box off of the upper attachments.
To ensure actuator movement with out removing upper I/P trim, place hand through glove compartment on top of HVAC case on actuator. Then rotate the air temperature switch while finger is on top of air temperature actuator driveshaft to feel movement.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the heating is insufficient. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the HVAC control module flash DTC 100? | Go to Step 3 | |
3 |
Does the blower motor operate in any of the speed positions? | Go to Step 4 | Go to Blower Motor Inoperative |
4 | Does the blower motor operate at the desired speed? | Go to Step 5 | Go to Blower Motor Malfunction |
Does the recirculation door move from the recirculation position to the outside air position? | Go to Step 6 | ||
6 |
Does the A/C compressor operate? | Go to Step 7 | |
7 | Perform the Heating Performance Diagnostic. Refer to Heating Performance Diagnostic in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | Go to Step 11 | Go to Step 8 |
Does the air temperature actuator rotate? | System OK | Go to Step 9 | |
9 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 10 |
10 |
Important: Perform the recalibration procedure for the HVAC control module. Refer to Actuator Recalibration . Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |